Before installing a mechanical seal, preparations must be made:
1. If the new machine seal is replaced, check whether the model and specification of the mechanical seal are correct and whether the quality meets the standard;
2. The anti-rotation groove end of the tail of the static ring and the top of the anti-rotation pin should maintain an axial clearance of 1mm-2mm to avoid buffer failure;
3. The end face of the moving and static ring is cleaned with alcohol, and the rest of the metal parts are cleaned with gasoline and dried with clean compressed air. Before assembly, the two "0" shaped rubber seals should be coated with a layer of lubricating oil, and the end faces of the moving and static rings should not be oiled.

 

The components of the mechanical seal and their related assembly contact surfaces must be cleaned with acetone or anhydrous alcohol before installation. The installation process should be kept clean, especially the dynamic and static rings and auxiliary sealing elements should be free of impurities and dust. The surface of the dynamic and static rings is coated with a layer of clean engine oil or turbine oil.

 